Construction Services

This page contains standard legends & details for construction documents being designed by Facilities Planning & Development Internal Design Team and constructed by Construction Services. Some details have been adopted from UM AEC for use on UMHHC designs.

Note: Installation details with "FPD" in the file name are specifically for Facilities Planning & Development Internal Design Team use. All other details are shared with outside A/E firms - CAD files can be found on the Standard Details page.

Architectural
Drawing Name
File Name
Architectural Standard Legend Sheet
  • A-0
  • Counter at Soiled Utility
  • D064040H-1
  • Plastic Laminate Counter with Grommet
  • D064040H-2
  • Standard Workstation Counter
  • D064040H-3
  • Pull Out Waste/Linen Cabinet - Plan & Elevation
  • D064040H-4a
  • Pull Out Waster/Linen Cabinet - Section
  • D064040H-4b
  • Sink Counter in Patient Room - Elevation & Section
  • D064040H-5
  • Clerk Station Elevations
  • D064040H-6
  • Privacy Panel - Elevation
  • D064040H-7a
  • Privacy Panel - Sections
  • D064040H-7b
  • Standard Multi-Person Office Aisle Clearances
  • D064040H-8
  • Corridor Mounting Requirements
  • D102800H-1
  • Toilet Accessories Elevation
  • D102800H-2

  • Mechanical
    Drawing Name
    File Name
    Mechanical Standard Legend Sheet
  • M-0
  • Pipe Sleeve Thru Floor
  • D221113H-1
  • Pipe Sleeve Thru Interior Wall
  • D221113H-2
  • End Suction Pump Installation Detail
  • D 15160 001
  • Pump Base Installation Detail
  • D 15160 002
  • Vertical Split Case Pump Installation Detail
  • D 15160 003
  • Vertical Split Case Pump Installation Detail
  • D 15160 005
  • End Suction Pump Installation Detail
  • D 15160 006
  • Typical Mixing Valve
  • D220010H-1
  • Automatic Water System Air Vent Detail
  • D 15515 002
  • Hot Water Heating Coil 2-way Control Valve Detail
  • D 15820 001
  • Hot Water Heating Coil 3-way Control Valve Detail
  • D 15820 002
  • Chilled Water Cooling Coil 3-way Control Valve Detail
  • D 15820 101
  • Chilled Water Cooling Coil 2-way Control Valve Detail
  • D 15820 102
  • Steam Heating Coil
  • D 15820 201
  • Draw-Thru Coil Condensate Drain
  • D 15830 001
  • Blow-Thru Coil Condensate Drain
  • D 15830 002
  • Duct-Mounted Reheat Coil - Hot Water Heating Piping Connections Detail
  • D 15830 101
  • Supply Air Diffuser with Flex Duct
  • D230022H-FPD-1
  • Return/Exhaust Air Grille
  • D230022H-FPD-2
  • Fire Damper - Wall Installation
  • D230022H-FPD-4
  • Fire Damper - Floor Installation
  • D230022H-FPD-5
  • Duct Elbow
  • D230020H-1
  • Typical Interstitial Level Box Installation
  • D230020H-2
  • Typical Interstitial Level Duct Support
  • D230020H-3
  • Typical Duct Tap
  • D230020H-FPD-1
  • Sample Duct Construction Schedule
  • T 15890 001
  • Sample Damper Construction Schedule
  • T 15895 001
  • Typical Terminal Box Installation
  • D230021H-1
  • Thermostat Mounting
  • D230930H-1
  • DP Sensor Detail
  • D 15975 001

  • Electrical
    Drawing Name
    File Name
    Electrical Standard Legend Sheet
  • E-0
  • Conduit Penetration at Interior Gyp. Board Wall
  • D260533H-FPD-1
  • Conduit Penetration at Interior Concrete/ CMU Wall
  • D260533H-FPD-2
  • Conduit Sleeve Thru Exterior Wall
  • D260533H-FPD-3
  • Conduit Sleeve Thru Floor
  • D260533H-FPD-4
  • Typical Dual Channel Wireway for Existing Walls
  • D260533H-FPD-5
  • Lay-in Grid Fluorescent Luminaire
  • D265100H-FPD-1
  • Downlight Luminaire
  • D265100H-FPD-2
  • Exit Luminaire
  • D265100H-FPD-3
  • Card Reader
  • D281600H-1
  • Card Reader - CVC
  • D281600H-2
  • Camera Ceiling Mount
  • D281600H-FPD-1
  • Typical Communication/ Data Outlet Installation
  • D272000H-FPD-1